site nameHitachi Cable
  Hitachi Cable Asia Pacific (HCAP) Pte Ltd
Hitachi


starting of primary navigation  Menu | UL2468 |  UL2651 |  UL20058  | UL20080 
ending of primary navigation
 
 FLAT RIBBON WIREstarting of main content Single Core Wire

                             Single Core Wire
Flat Ribbon Wire

UL STYLE       : 2468
Rating             : 80 °C, 300V (UL); 90 °C, 300V (CSA)
Standards       :  UL 758, CSA C22.2 No.210.2
Usage             :  For internal wiring of audio/video/multimedia equipment

Conductor
Insulation

Conductor Resistance
at 20oC
(Max)
W/km

Approx. weight   kg/km
Unit length coil m
Type    
No    
Size   AWG
Stranding   No./mm
Diameter   mm
Insulation Thickness mm
Thickness (A) mm
Width  (B)  mm
TASC
2
26
7/0.16
0.48
0.44 
1.36
2.80
139
6
305
3
4.30
10
4
5.80
13
5
7.30
17
6
8.80
20
153
7
10.30
24
8
11.80
27
153*
9
13.30
30
10
14.80
34
11
16.30
37
12
17.80
41
13
19.30
44
14
20.80
48
15
22.30
51
2
24
7/0.203
0.61 
1.48 
3.48
87.6 
8
305 
3
5.48
13
4
7.48
17
5
9.48
22
6
11.48
26
153 
7
13.48
30
8
15.48
35
153* 
9
17.48
39
10
19.48
43
11
21.48
48
12
23.48
52
13
25.48
56
14
27.48
61
15
29.48
65
*Single Layer Coil

1.Product Description

a) Conductor : Tinned Annealed Copper wire (TA) or Tin Over Coated Tinned Annealed stranded Copper wire (TASC)
b) Insulation : Heat resistance leadfree PVC. Black colour

2.Features

a) Flammability : VW-1 (UL), FT1 (CSA), -F- (DENTORI).
b) Easy insertion to through-holes of PCB
c) Can be used with Insulation Displacement Contact(IDC) connectors

3. Wire Marking

AWM E41447-HCS STYLE 2468 26AWG VW-1 HITACHI CSA AWM LL49508
I A/B 90C 300V FT1 HCS -F- LF
**Conductor Size

4.Safety Standards No.

a) UL : E41447, CSA : LL49508, F-Mark : F-HCS1-003(2-7c), F-HCS1-012(8c).

5. Ordering Information

a) Contact us at mailto:sales@hitachicable.com.sg